The
'Next Generation' Digital Multimeter (Protek 506)
True RMS, 3-3/4 Digits, RS-232C Interface 4000 Count, Auto-Ranging, Analog
Bargraph 10MHz Freq. Counter & Much More! We Even Include the temp adaptor
& k-type probe!
Item Name: Protek 506 Meter
Item Number: Protek 506 Meter
 

Click picture for larger view of datalogging in action.
|
506 - 3 3/4 Digit DMM with Temp, Freq and Capacitance
|
|
|
| |
|
|
|
| • |
Dual display for
Frequency, AC voltage and Temperature measurements |
| • |
True RMS AC Voltage,
Current and DB Readings |
| • |
RS-232 interface &
software, 10 location memory |
| • |
Min, Max, Avg and
Relative modes |
| • |
Capacitance,
Inductance, Frequency and Temp measurements |
| • |
Square wave
generator, logic function and back light |
|
|
|
|
| |
|
|
|
|
|
|
| |
|
SPECIFICATIONS
|
|
|
|
|
Ranges (5) |
400mV to 1000V |
|
Best
Resolution |
0.1mV |
|
Accuracy |
± (0.5% Rdg + 2D) |
|
|
|
|
|
Ranges (5) |
400mV to 750V |
|
Best
Resolution |
0.1mV |
|
Accuracy |
± (1.5% Rdg + 5D) |
|
|
|
|
|
Ranges |
400µA, 400mA, 20A |
|
Best
Resolution |
0.1µA |
|
Accuracy |
± (1% Rdg + 2D) |
|
|
|
|
|
Ranges |
400µA, 400mA, 20A |
|
Best
Resolution |
0.1µA |
|
Accuracy |
± (1.5% Rdg + 2D), 50Hz to 100Hz |
|
|
|
|
|
Ranges (6) |
400W to 40MW |
|
Best
Resolution |
0.1W |
|
Accuracy |
± (0.5% Rdg + 2D) |
|
|
|
|
|
Ranges (4) |
-31.6 to + 59.71dB |
|
Best
Accuracy |
±0.5dB |
|
|
|
|
|
Buzzer |
Sound at < 100W
. |
|
Display
Will Read |
Short when R < 100W
Open when R > 100W |
|
|
|
|
|
Display Will Read |
Shrt when V < 0.5V
Good when V = 0.5V to 1V
Open when V > 1V |
|
|
|
|
|
Ranges (4) |
10kHz to 10MHz |
|
Best
Resolution |
1Hz |
|
Accuracy |
± (0.01% Rdg ± 1D) |
|
Sensitivity |
1.5V RMS |
|
|
|
|
|
Range |
-17 to 1200°C (0 to 2000°F) |
|
Resolution |
1°C and 1°F |
|
Accuracy |
± (3% Rdg + 3D) |
|
|
|
|
|
TLL Level Display Will Read |
Lo when V is < 0.8V
Hi when V is > 2.0V
W when V is 0.8V to 2.0V |
|
|
|
|
|
Range |
0 to
100µF |
|
Resolution |
0.01µF |
|
Accuracy |
± (3% Rdg + 5D) |
|
|
|
|
|
Range |
0 to 100H |
|
Resolution |
0.01H |
|
|
|
|
|
Signal Out |
2048Hz, 4096Hz, 8192Hz Square wave |
|
Timer
Range |
1 second to 10 hours |
|
RS-232 Interface |
1200bps, 9 Pin Connector |
|
|
|
|
|
Size |
8.0" H × 3.6" W × 1.5" D |
|
Weight |
1 lb. |
|
Power |
9V battery |
|
Supplied
Accessories |
Manual, Test leads,
Holster, Temp adapter, "K" type temp probe, RS-232 cable and
Software |
|
MSRP (suggested price) |
$193.70 |
|
|
|
|
- True RMS Mode
- Dual Display for Frequency, AC Voltage and Temperature
- RS-232C Interface
- 10 Location Memory
- Time Mode with Alarm, Clock and Stop Watch
- Min., Max., Avg. and Relative Mode
- Decibel Measurement
- Capacitance and Inductance Measurement
- Temperature Mode (°C/°F)
- Includes Type K Temperature Probe
- Pulse Signal Injection Function for Logic and Audible Testing, Etc.
- Continuity and Diode Test
- Logic Test
- Auto Power Off and "Keep On" Mode
- Fuse 20A Input with Warning Beeper
- Back Light
- Data Hold and Run Mode
- Low Battery Indication Mode
- Over Load Protection and Safety Design in Compliance with UL 1244 and
VDE-0411
- Protective Holster
- Silicon Coated Test Leads
10MHz Frequency Counter and AC Voltage (V) Dual-Display-
The 3-3/4 digit, 4000 count meter provides an accurate digital readout of
frequency and AC voltage in dual display mode.
AC Voltage and Decibel (dBM) Dual-Display-
This meter
provides AC voltage along with dBM function in the dual display mode. You can
easily measure the dB gain of amplifiers or insertion loss of filters,
attenuators, etc.
Capacitance and Inductance function-
Tests
capacitance to 100µF and inductance to 100H.
Diode Testing-
Checks diodes and other semiconductors
for open, short or good. It also displays the diode's forward voltage drop in
the dual display mode.
Temperature Function-
In dual display mode, the meter
will automatically display the temperature in celsius (°C) and fahrenheit (°F)
on the LCD. Also, the meter can measure from -17°C to 1,093°C by using
optional temp adaptor and k-type thermocouple probe.
Logic Test-
Easily checks digital circuits to
determine the logic state of different parts of the circuit. The meter displays
the high, low & . . . on the main-display with actual measured value on the
sub-display.
Pulse Signal Out Function-
This meter can generate
2KHz, 4KHz, 8KHz pulse signals at sig-out terminal. This function enables you to
easily test logic or audio circuits.
RS-232C PC Interface-
The model 506 meter has a
RS-232C serial interface. Measured values are transmitted to the computer via an
interface cable and supplied software (both DOS & Windows versions are
supplied).
Time (9:59:59) Function-
This meter has a time
function which can measure time up to 10 hours (9:59:59) and also it has a stop
watch function. Alarm sounds at end of selected time interval.
Minimum, Maximum and Average (Min., Max., Avg.) Mode-
Min.,
Max. and Avg. allow you to measure and record the minimum, maximum and running
average of both positive and negative polarity input signals. Min. and Max.
operates with all available functions.
10 Memories- You can store into memory 10
measurements. Data can be recalled at anytime using the menu and the up(s) and
down(t) buttons.
Relative (D, %) Function- Relative
mode allows you to measure values with respect to a preset reference value. The
results are displayed on the LCD as D and %. Relative mode operates with all
functions.
|
|